mcr PROSMOKE AUTOMATIC SMOKE CURTAINS

Price: $0.00
Tax excluded

mcr PROSMOKE AUTOMATIC SMOKE CURTAINS

DESCRIPTION    

  • automatic smoke curtains FS and CE are responsible for separation of smoke zones within the building, and stop smoke from spreading within passages, on staircases or escalators
  • automatic smoke curtains are used in buildings where the visual aspect of building plays an important role
  • fire resistance parameters:
      automatic curtains FS: D30 / DH60 lub D180 
      automatic curtains CE: D30 / DH60 / DH30 / DH60
  • vast range of curtain mounting to ceiling lintel or object steel construction
  • automatic curtain as one folded or modular device can be connected under an angle or contain evacuation entrance
  • painting steel components with chosen RAL palette colour
  • classification (as per EN 12101) according to:
      Certificate of constancy of performance 1396-CPR-0033 
        (mcr PROSMOKE FS curtains)
      Certificate of constancy of performance 1396-CPR-0021 
        (mcr PROSMOKE CE curtains)
Mercor ASC Models
Share

mcr PROSMOKE AUTOMATIC SMOKE CURTAINS

DESCRIPTION    

  • automatic smoke curtains FS and CE are responsible for separation of smoke zones within the building, and stop smoke from spreading within passages, on staircases or escalators
  • automatic smoke curtains are used in buildings where the visual aspect of building plays an important role
  • fire resistance parameters:
      automatic curtains FS: D30 / DH60 lub D180 
      automatic curtains CE: D30 / DH60 / DH30 / DH60
  • vast range of curtain mounting to ceiling lintel or object steel construction
  • automatic curtain as one folded or modular device can be connected under an angle or contain evacuation entrance
  • painting steel components with chosen RAL palette colour
  • classification (as per EN 12101) according to:
      Certificate of constancy of performance 1396-CPR-0033 
        (mcr PROSMOKE FS curtains)
      Certificate of constancy of performance 1396-CPR-0021 
        (mcr PROSMOKE CE curtains)

DESIGN
Base

  • mcr PROSMOKE CE – automatic smoke curtain
    (rolled and unrolled with motor)
  • mcr PROSMOKE FS – automatic smoke curtain
    (fail-safe gravitational drop)

Automatic curtain - structure

  • steel sheet casing with roller
  • incombustible fabric
  • motor
  • bottom balast
  • masking element
  Separation of smoke zones

 

Separated smoke zones stop the spread of smoke in passageways, staircases, stairs and hold the smoke in a room adjacent to the evacuation route. Correct arrangement of smoke curtains in the facility allows the smoke to be directed towards other system devices - smoke vents.

 Smoke flow optimisation
       and gas redirection into smoke vents

 

Proper placement of smoke curtains in a building makes it possible
to direct the smoke towards other elements of the system, i.e. smoke vents.

 Non-standard options

 

» elements painted to any RAL colour
» service passage
» guides

 Application

 

Wide scope of shapes and sizes enable installation on warehouses,
public services buildings, shopping malls, commercial and sport objects

  • Brand

  • Non-standard options
    » elements painted to any RAL colour
    » guides
    » service passage
  • Separation of smoke zones
    Separated smoke zones stop the spread of smoke in passageways, staircases, stairs and hold the smoke in a room adjacent to the evacuation route. Correct arrangement of smoke curtains in the facility allows the smoke to be directed towards other
  • Smoke flow optimisation and gas redirection into smoke vents
    Proper placement of smoke curtains in a building makes it possible to direct the smoke towards other elements of the system, i.e. smoke vents.
  • fire resistance parameters:
    – automatic curtains CE: D30 / DH60 / DH30 / DH60
    – automatic curtains FS: D30 / DH60 lub D180
  • Automatic curtain - structure
    bottom balast
    incombustible fabric
    masking element
    motor
    steel sheet casing with roller

PROSMOKE-FS-1396-CPR-0033_EN

PROSMOKE-FS-1396-CPR-0033_EN

Download (1.15MB)

PROSMOKE-CE-1396-CPR-0021_EN

PROSMOKE-CE-1396-CPR-0021_EN

Download (1.16MB)

DTR_MCR_PROSMOKE

DTR_MCR_PROSMOKE_FSv2_CE_v3.1.0_EN.DOCX

Download (1.86MB)

DTR_MCR_PROSMOKE

DTR_MCR_PROSMOKE_CE_CE1_v3.1.1_en.doc

Download (1.77MB)

2024_Technical

2024_Technical_Catalogue_mcr PROSMOKE_Smoke curtains__WWW

Download (2.01MB)

2023_FOLDER

2023_FOLDER_PROSMOKE_WWW_EN

Download (732.1KB)
Security policy
(edit with the Customer Reassurance module)
Delivery policy
(edit with the Customer Reassurance module)
Return policy
(edit with the Customer Reassurance module)

You might also like

Comments (0)

No customer reviews for the moment.
Loading...
Back to top