Model GPD – Diesel Engine Fire Pump Controllers, Nema II

Price: $4,500.00
Tax excluded

Model GPD – Diesel Engine Fire Pump Controllers, Nema II

Opsional Add Ons
Share

Model GPD – Diesel Engine Fire Pump Controllers, Nema II

  • ViZiTouch 2.1 operator interface
  • Enclosure: IP55
  • Pressure and event recorder
  • Battery voltage and amperage display
  • Run Test push button
  • HAND – OFF – AUTO selector switch
  • Manual crank pushbuttons (2)
  • Stop pushbutton
  • Remote start / deluge valve start provision
  • Pressure transducer and run test solenoid valve externally mounted
  • Gland plate
  • Alarm buzzer
  • Alarm contacts for remote indication
  • Weekly exercise programmable time clock
  • Crank cycle
  • Programmable automatic shutdown (minimum run timer)
  • Programmable sequential start timer (delay start timer)

 Enclosure assembly ratings Standard paint specifications (does not apply to brushed finish enclosures):- Red RAL3002- Powder coated / glossy textured finish NEMA 4 enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); and that will be undamaged by the external formation of ice on the enclosure. NEMA 4X enclosures provide an additional level of protection against corrosion.*** D2 NEMA 4 assembly D3A NEMA 4X assembly stainless steel-304 painted red D3B NEMA 4X assembly stainless steel-304 brushed finish D3C NEMA 4X assembly stainless steel-316 painted red D3D NEMA 4X assembly stainless steel-316 brushed finish D1 NEMA 12 assembly Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).*** D1A NEMA 3R assembly Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.*** D20 NEMA 3 assembly Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel again access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.*** D21 IP54 assembly Red RAL3002 Stainless Steel Brushed Finish Dust Protected - Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact. Splashing water - Water splashing against the enclosure from any direction shall have no harmful effect.** D22 IP55 assembly Dust Protected - Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact. Water jets - Water projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects.** — GPD D23 IP56 assembly Dust Tight - No ingress of dust; complete protection against contact. Water jets - Water projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects.** D24 IP66 assembly Dust Tight - No ingress of dust; complete protection against contact. Powerful water jets - Water projected in powerful jets (12.5mm nozzle) against the enclosure from any direction shall have no harmful effects.*

  • Brand

  • Approvals
    CE
    FM
    UL
  • Diesel Engine Controller Nema Option
    D1A NEMA 3R assembly
    D2 NEMA 2 : Standart
    D21 IP54 assembly
    D22 IP55 assembly
    D23 IP56 assembly
    D24 IP66 assembly
    D3A NEMA 4X assembly stainless steel-304 painted
    D3B NEMA 4X assembly stainless steel-304 brushed finish
    D3D NEMA 4X assembly stainless steel-316 brushed finish

Diesel Controller

Diesel Controller

Download (3.88MB)
Security policy
(edit with the Customer Reassurance module)
Delivery policy
(edit with the Customer Reassurance module)
Return policy
(edit with the Customer Reassurance module)

You might also like

Comments (0)

No customer reviews for the moment.
Loading...
Back to top