Model GPD – Diesel Engine Fire Pump Controllers, Nema II
Model GPD – Diesel Engine Fire Pump Controllers, Nema II
Model GPD – Diesel Engine Fire Pump Controllers, Nema II
- ViZiTouch 2.1 operator interface
- Enclosure: IP55
- Pressure and event recorder
- Battery voltage and amperage display
- Run Test push button
- HAND – OFF – AUTO selector switch
- Manual crank pushbuttons (2)
- Stop pushbutton
- Remote start / deluge valve start provision
- Pressure transducer and run test solenoid valve externally mounted
- Gland plate
- Alarm buzzer
- Alarm contacts for remote indication
- Weekly exercise programmable time clock
- Crank cycle
- Programmable automatic shutdown (minimum run timer)
- Programmable sequential start timer (delay start timer)
Enclosure assembly ratings Standard paint specifications (does not apply to brushed finish enclosures):- Red RAL3002- Powder coated / glossy textured finish NEMA 4 enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); and that will be undamaged by the external formation of ice on the enclosure. NEMA 4X enclosures provide an additional level of protection against corrosion.*** D2 NEMA 4 assembly D3A NEMA 4X assembly stainless steel-304 painted red D3B NEMA 4X assembly stainless steel-304 brushed finish D3C NEMA 4X assembly stainless steel-316 painted red D3D NEMA 4X assembly stainless steel-316 brushed finish D1 NEMA 12 assembly Enclosures constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (dripping and light splashing).*** D1A NEMA 3R assembly Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.*** D20 NEMA 3 assembly Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel again access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.*** D21 IP54 assembly Red RAL3002 Stainless Steel Brushed Finish Dust Protected - Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact. Splashing water - Water splashing against the enclosure from any direction shall have no harmful effect.** D22 IP55 assembly Dust Protected - Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact. Water jets - Water projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects.** — GPD D23 IP56 assembly Dust Tight - No ingress of dust; complete protection against contact. Water jets - Water projected by a nozzle (6.3mm) against enclosure from any direction shall have no harmful effects.** D24 IP66 assembly Dust Tight - No ingress of dust; complete protection against contact. Powerful water jets - Water projected in powerful jets (12.5mm nozzle) against the enclosure from any direction shall have no harmful effects.*
-
ApprovalsCE
FM
UL -
Diesel Engine Controller Nema OptionD1A NEMA 3R assembly
D2 NEMA 2 : Standart
D21 IP54 assembly
D22 IP55 assembly
D23 IP56 assembly
D24 IP66 assembly
D3A NEMA 4X assembly stainless steel-304 painted
D3B NEMA 4X assembly stainless steel-304 brushed finish
D3D NEMA 4X assembly stainless steel-316 brushed finish