DESCRIPTION

  • mcr PROSMOKE ST fixed smoke curtains are used for separating smoke zones in large hall buildings, mainly production and storage halls, where no limitations to the loading of bearing structure of the building exist
  • fire resistance parameters: DH120 (steel)
  • made of TR35 trapezoidal steel sheet of 0.5 mm thickness, zinc coated, Al-Zn or polyester paint
  • load bearing element of mcr PROSMOKE ST curtain shaped as angle or flat profile made of galvanized or painted steel sheet
  • various options for mounting the curtain of the steel structure
  • painting steel components with chosen RAL palette colour
  • Certificate of constancy of performance CE nr 1396-CPR-0037, Product acquires CE mark confirming compatibility with EN 12101-1
Quantity

  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

  •  PROSMOKE ST curtain shaped as angle or flat profile made of galvanized or painted steel sheet
  • various options for mounting the curtain of the steel structure
  • painting steel components with chosen RAL palette colour
  • Certificate of constancy of performance CE nr 1396-CPR-0037, Product acquires CE mark confirming compatibility with EN 12101-1

 


DESIGN
Base

  • mcr PROSMOKE ST  fixed steel curtain

Fixed control steel curtain - structure

  • trapezoidal metal sheet
  • load bearing and bracing elements 

  Separation of smoke zones

 

Separated smoke zones stop the spread of smoke in passageways, staircases, stairs and hold the smoke in a room adjacent to the evacuation route. Correct arrangement of smoke curtains in the facility allows the smoke to be directed towards other system devices - smoke vents.

 Smoke flow optimisation
       and gas redirection into smoke vents

 

Proper placement of smoke curtains in a building makes it possible
to direct the smoke towards other elements of the system, i.e. smoke vents.

 Non-standard options

 

installation passages in fixed curtains
» additional bracing elements used for steel curtains of height ≥ 2.5 m:
 steel angle along curtain, up to its mid-height, 
 angle profiles made of steel squared pipe, placed every 3 m 
» elements painted to any RAL colour
» service passage
» guides

Data sheet

Approvals
CE
CPR
Non-standard options
installation passages in fixed curtains
» elements painted to any RAL colour
» service passage
– angle profiles made of steel squared pipe, placed every 3 m
fire resistance parameters:
DH120 (steel)
Comments (0)