mcr PASAT - ROOF SMOKE EXHAUST FAN
mcr Pasat
roof smoke exhaust fan
» CE – according to EN 12101-3
» Fire resistance rating:
- F400 – 400°C for 120 minutes
- F600 – 600°C for 60 minutes
The mcr Pasat roof smoke exhaust fan with centrifugal rotor is intended to evacuate the smoke
and hot air from rooms during a fre and for comfort ventilation.
Key details
Fire resistance classes:
- class F600 – fire resistance 600°C/60 min. certified for conformance with EN13501-4:2016
- class F400 – fire resistance 400°C/120 min. certified for conformance with EN13501-4:2016
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
mcr PASAT - ROOF SMOKE EXHAUST FAN
Key details
Fire resistance classes:
- class F600 – fire resistance 600°C/60 min. certified for conformance with EN13501-4:2016
- class F400 – fire resistance 400°C/120 min. certified for conformance with EN13501-4:2016
Additional details
Certificate of Constancy of Performance: 2434-CPR-0221
Roof smoke exhaust fans type mcr Pasat with radial rotor are designed for removing smoke and hot air from rooms during fire, and for comfort ventilation. They may feature one-speed or two-speed engines and combine comfort function with fire function, e.g. for ventilating and de-smoking underground garages, malls, production halls.
Smoke exhaust fans facilitate evacuation of humans and equipment from rooms covered by fire; they allow for a quicker and more effective firefighting operation, also protecting the building structure and its equipment from high temperature, and preventing propagation of fire, fire gases and smoke to neighbouring fire zones. The devices are adapted for outdoor work in vertical working position.
FEATURES
- F600, F400 fire resistance classes
- two-gear variants for mixed ventilation
- comprehensive, certified accessories
- aluminium enclosure - lightweight
APPLICATION
- PRODUCTION HALLS AND WAREHOUSES
- LOGISTICS CENTERS
- PUBLIC BUILDINGS
- COMMERCIAL BUILDINGS
- RESIDENTIAL BUILDINGS
ADDITIONAL DESCRIPTION
Making variants:
- one-speed
- two-speed
Accessories:
- PD, PD-T roof bases
- KD rounded elastic joints
- PK counterflanges
- KS automatic backdraft dampers
- WS service switches
Fan making without fire resistance available as an option (BO version).
Data sheet
- Approvals
- CE
- Fire resistance classes:
- class F400
class F600 - efficiency up to (m3/h)
- 50 000
- compression up to (Pa)
- 1 950
- nominal power (kW)
- 0.75 kW - 37 kW
- rotation speeds n (RPM)
- 750
1000
1500