mcr LAM LOUVERED VENTS
search
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS
  • mcr LAM LOUVERED VENTS

mcr LAM LOUVERED VENTS

mcr LAM LOUVERED VENTS

DESCRIPTION

  • mcr LAM louvered smoke vents are assembled
    to roof slope with various angles and facades
  • due to its construction louvered vents are resistant to wind
    and can be installed to roofs and high building facades
  • a wide range of dimensions allows for obtaining the required active
    surface venting or aeration
  • wide scope of sizes: 80 cm x 50 cm ÷ 380 cm x 250 cm
  • bottom part of the base has a circumferential flange of width 100 mm,
    through which the base is fitted to the roof structure
  • upper part of base has shape enabling water runoff
  • RAL palette colour selection for vent elements
  • opening angle of the flap blades 90°
  • classification as per Certificate of Conformity in accordance with EN 12101-2
    (CE Certificate) 
LAM LOUVERED VENTS SIZES: 80 x 50
  Security policy

(edit with the Customer Reassurance module)

  Delivery policy

(edit with the Customer Reassurance module)

  Return policy

(edit with the Customer Reassurance module)

mcr LAM LOUVERED VENTS 

DESCRIPTION

  • mcr LAM louvered smoke vents are assembled
    to roof slope with various angles and facades
  • due to its construction louvered vents are resistant to wind
    and can be installed to roofs and high building facades
  • a wide range of dimensions allows for obtaining the required active
    surface venting or aeration
  • wide scope of sizes: 80 cm x 50 cm ÷ 380 cm x 250 cm
  • bottom part of the base has a circumferential flange of width 100 mm,
    through which the base is fitted to the roof structure
  • upper part of base has shape enabling water runoff
  • RAL palette colour selection for vent elements
  • opening angle of the flap blades 90°
  • classification as per Certificate of Conformity in accordance with EN 12101-2
    (CE Certificate)

DESIGN
Base

  • height: 15 ÷ 25 cm
  • material: steel, aluminum
  • thermal insulation with mineral wool of 20 mm thickness

Filling

  • multi-chamberpolycarbonate PCA 16 mm  or PCA 25 mm panel
  • non-insulated  aluminum sheets (opaque filling - SO)
  • aluminum sheet isolated with ISO panel of thickness 20 mm (opaque filling - SO+ISO*)
    * insulating material

Blades

  • types: transparent, non-transparent
  • structure: aluminum profiles, multi-chamber polycarbonate
    or aluminum insulated/ noninsulated sheet

Control system

  • smoke exhaust: electric: (24 V-), pneumatic
  • ventilation: electric (230~)
 Smoke exhaust

 

Exhaust smoke, combustion gases and heat energy from enclosed spaces (production floors, storage spaces, public facilities, etc.) to the outside of builings, in order to protect human lives and property.

 Lighting

 

Effective method of increasing natural light intensity in rooms and contribute to reducing total cost of energy.

 Ventilation

 

Provides air supply and daily ventilation.

 Additional elements

 

» rain shield
» thermo switch
» limit switch
» steel plinth for mounting on the roof

 Heat transfer
 

Product allows to achieve high heat transfer:

Urc ≥ 1,41 W/m²K.
 Application

 

Wide scope of shapes and sizes enable
installation on warehouses, public
services buildings, shopping malls,
commercial and sport objects.

Data sheet

Approvals
CE
CPR
HIGIENIC
Heat transfer
Urc ≥ 1,41 W/m²K.
Lighting
Effective method of increasing natural light intensity in rooms and contribute to reducing total cost of energy.
Smoke exhaust
Exhaust smoke, combustion gases and heat energy from enclosed spaces (production floors, storage spaces, public facilities, etc.) to the outside of builings, in order to protect human lives and property.
Additional elements
» limit switch
» rain shield
» steel plinth for mounting on the roof
» thermo switch
LAM Filling
multi-chamberpolycarbonate PCA 16 mm or PCA 25 mm panel
LAM Blades structure
aluminum insulated
aluminum profiles
multi-chamber polycarbonate
noninsulated sheet
Filling
aluminum sheet isolated with ISO panel of thickness 20 mm (opaque filling - SO+ISO*) * insulating material
multi-chamberpolycarbonate PCA 16 mm
multi-chamberpolycarbonate PCA 25 mm panel
non-insulated aluminum sheets (opaque filling - SO)
DESIGN Base material
aluminum
steel
DESIGN Base insulation
thermal insulation with mineral wool of 20 mm thickness

Download

OMM - mcr LAM

OMM - mcr LAM louvered natural smoke & heat exhaust ventilators (HO.21.01028 rev.C)

Download (1.69MB)

certyfikate

certyfikat-_1396-cpr-0032_mcr_lam

Download (1.86MB)

Higienic Certificate

Atest Higieniczny-Higienic Certificate_mcr LAM & LAM-N (HO.23.02881)

Download (411.32KB)

2024_Technical_Catalogue

2024_Technical_Catalogue_mcr LAM_Louvered smoke vents_EN_WWW

Download (886.67KB)

You might also like

Comments (0)
No customer reviews for the moment.