Automatic fire sprinklers are the final element of a sprinkler system: they sense heat at the point of fire and discharge water directly onto it. Our catalogue covers pendent, upright, sidewall, concealed, extended coverage, ESFR and residential sprinklers, plus spray nozzles.

When selecting a sprinkler, check the bulb temperature rating against the ambient temperature, the K-factor, the response type (quick or standard) and the UL/FM listing. Send us the product name or code and we will reply quickly with price and availability.

Nozzles

Nozzles

LT56C Series Hallway Sprinklers, Concaled – Fire Sprinkler

LT56C Series Hallway Sprinklers, Concaled

F156 Sprinkler, Vertical Sidewall Wall type, SR, K 80, ½"" Npt – Sidewall Sprinkler

F156 Sprinkler, Vertical Sidewall Wall type, SR, K 80, ½"" Npt

000630

G4 Sprinkler Concealed Plate Ral 8003, 57Degree – Concealed Sprinkler

G4 Sprinkler Concealed Plate Ral 8003, 57Degree

000449

Model HL22 ESFR Pendent Sprinkler – ESFR Sprinkler

Model HL22 ESFR Pendent Sprinkler

Series ELO-231B – 11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage

Series ELO-231B – 11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage

Series TY-B Fire Sprinkler , Standard Response , Standard Coverage 3/4"" NPT

Series TY-B Fire Sprinkler , Standard Response , Standard Coverage 3/4"" NPT

Model ESFR-25 25.2 K-factor Pendent Sprinkler Early Suppression, Fast Response – ESFR Sprinkler

Model ESFR-25 25.2 K-factor Pendent Sprinkler Early Suppression, Fast Response

F1 Pendent Sprinkler, Standard Response, K:115, ¾"" Npt

F1 Pendent Sprinkler, Standard Response, K:115, ¾"" Npt

F156 Sprinkler, Horizontal Wall type, ST, K 80, ½"" Npt – Fire Sprinkler

F156 Sprinkler, Horizontal Wall type, ST, K 80, ½"" Npt

Model K17-231 Sprinkler 16.8 K-Factor Standard Response – Fire Sprinkler

Model K17-231 Sprinkler 16.8 K-Factor Standard Response

Model K17-231 Sprinkler 16.8 K-Factor Standard Response, Standard Coverage Upright Sprinklers

Model K17-231 Sprinkler 16.8 K-Factor Standard Response, Standard Coverage Upright Sprinklers

Model ESFR-17 Sprinklers - Upright Early suppression, fast response – ESFR Sprinkler

Model ESFR-17 Sprinklers - Upright Early suppression, fast response

Model ESFR-17 Sprinklers - Pendent – ESFR Sprinkler

Model ESFR-17 Sprinklers - Pendent

Issue A and B Window Type Sprinklers For window protection against fire – Fire Sprinkler

Issue A and B Window Type Sprinklers For window protection against fire

High-Velocity Directional Spray Nozzles Powerful spray nozzle protection

High-Velocity Directional Spray Nozzles Powerful spray nozzle protection

Series DS-1 Dry Sprinklers Standard – Fire Sprinkler

Series DS-1 Dry Sprinklers Standard

Medium-Velocity Directional Spray Nozzles Open medium velocity, external deflector - for high-risk areas

Medium-Velocity Directional Spray Nozzles Open medium velocity, external deflector - for high-risk areas

Type D3 Protectospray Nozzles Directional spray nozzles

Type D3 Protectospray Nozzles Directional spray nozzles

Type 1 and 2 Cooling Tower Nozzles, Crossflow

Type 1 and 2 Cooling Tower Nozzles, Crossflow

Ultra K17 Sprinkler – Fire Sprinkler

Ultra K17 Sprinkler

ESFR-17 Electronically Controlled Sprinkler For Use in the EAS-1 Electronically Activated Sprinkler System – ESFR Sprinkler

ESFR-17 Electronically Controlled Sprinkler For Use in the EAS-1 Electronically Activated Sprinkler System

Ultra K34 Sprinkler – Fire Sprinkler

Ultra K34 Sprinkler

Series TY-FRB Sprinklers Offered in a variety of K-factors and orientations – Fire Sprinkler

Series TY-FRB Sprinklers Offered in a variety of K-factors and orientations

Model RFII HSW Sprinkler 5.6 K-factor horizontal sidewall flat plate concealed sprinklers

Model RFII HSW Sprinkler 5.6 K-factor horizontal sidewall flat plate concealed sprinklers

Model RFII MRI Standard Coverage Sprinklers 5.6 K-factor non-magnetic concealed pendent sprinklers – Concealed Sprinkler

Model RFII MRI Standard Coverage Sprinklers 5.6 K-factor non-magnetic concealed pendent sprinklers

Attic Sprinklers Specific application sprinklers for protecting attics – Fire Sprinkler

Attic Sprinklers Specific application sprinklers for protecting attics

Series RFII Standard Coverage Sprinkler 5.6 K-factor Royal Flush II Concealed Pendent Sprinklers – Concealed Sprinkler

Series RFII Standard Coverage Sprinkler 5.6 K-factor Royal Flush II Concealed Pendent Sprinklers

Illusion Standard Coverage Sprinkler Extra-large orifice concealed pendent sprinklers – Concealed Sprinkler

Illusion Standard Coverage Sprinkler Extra-large orifice concealed pendent sprinklers

Series TY-B Fire Sprinkler , Standard Response , Standard Coverage 1/2"" NPT

Series TY-B Fire Sprinkler , Standard Response , Standard Coverage 1/2"" NPT

LT56 Series “Hallway” Sprinklers – Fire Sprinkler

LT56 Series “Hallway” Sprinklers

D-3-4-6 KOW Flat Fan Spray Nozzle

D-3-4-6 KOW Flat Fan Spray Nozzle

08-KOW-Nozzles

08-KOW-Nozzles

07-ROY-Nozzles

07-ROY-Nozzles

Model ESFR-22 Sprinkler Early suppression, fast response – ESFR Sprinkler

Model ESFR-22 Sprinkler Early suppression, fast response

Model EC-25 Sprinkler Uprigh CMSA – Fire Sprinkler

Model EC-25 Sprinkler Uprigh CMSA

Model ESFR-34 Sprinkler, Pendent – ESFR Sprinkler

Model ESFR-34 Sprinkler, Pendent

N252EC CMDA/CMSA Pendent Sprinklers

N252EC CMDA/CMSA Pendent Sprinklers

N28T6 & N28T3 Specific Application ESFR Pendent Sprinklers – ESFR Sprinkler

N28T6 & N28T3 Specific Application ESFR Pendent Sprinklers

LB11 Horizontal Sidewall Storage Sprinkler – Sidewall Sprinkler

LB11 Horizontal Sidewall Storage Sprinkler

Model GL112 Upright Storage Sprinkler – Upright Sprinkler

Model GL112 Upright Storage Sprinkler

J112 EC OH ¾"" Upright Fire Sprinkler – Upright Sprinkler

J112 EC OH ¾"" Upright Fire Sprinkler

J168 Upright Storage Sprinkler – Upright Sprinkler

J168 Upright Storage Sprinkler

Fire Sprinkler Head, Model F1RES49, R3516, 4.9K, 1/2"", Concealed, Quick Response, Residential Pendent, 155 Degree – Concealed Sprinkler

Fire Sprinkler Head, Model F1RES49, R3516, 4.9K, 1/2"", Concealed, Quick Response, Residential Pendent, 155 Degree

RASCO/Reliable Model B Open Window Spray Nozzle

RASCO/Reliable Model B Open Window Spray Nozzle

Concealed SWC Escutcheon - White 135 Degree – Concealed Sprinkler

Concealed SWC Escutcheon - White 135 Degree

Fire Sprinkler Head, Model G5-56, RA3415, Gizli , 5.6K, Sarkık , 1/2"" NPT

Fire Sprinkler Head, Model G5-56, RA3415, Gizli , 5.6K, Sarkık , 1/2"" NPT

Fire Sprinkler Head, Model F1FR56, RA1414, 5.6K, 1/2"", Quick Response, Pendent – Pendent Sprinkler

Fire Sprinkler Head, Model F1FR56, RA1414, 5.6K, 1/2"", Quick Response, Pendent

Fire Sprinkler Head, Model F1FR80, R3622 and RA6322, 8.0K, 3/4"", Quick Response, Upright – Upright Sprinkler

Fire Sprinkler Head, Model F1FR80, R3622 and RA6322, 8.0K, 3/4"", Quick Response, Upright

Fire Sprinkler Head, Model F1FR56, RA1425, 5.6K, 1/2"", Quick Response, Upright – Upright Sprinkler

Fire Sprinkler Head, Model F1FR56, RA1425, 5.6K, 1/2"", Quick Response, Upright

Fire Sprinkler Head, F1-56, RA1325, 5.6K, 1/2"", Standard Response, Pendent – Pendent Sprinkler

Fire Sprinkler Head, F1-56, RA1325, 5.6K, 1/2"", Standard Response, Pendent

Series EC-14 Sprinklers Bulb style upright and pendent sprinklers

Series EC-14 Sprinklers Bulb style upright and pendent sprinklers

High Velocity Spray Nozzle (3/4 Inch)

High Velocity Spray Nozzle (3/4 Inch)

Medium Velocity Spray Nozzle

Medium Velocity Spray Nozzle

Varsha - 50 – Fire Sprinklers & Nozzles

Varsha - 50

Fire Sprinkler Head, Tyco Ultra K17, TY7153, 16.8K, Upright, 3/4"" NPT – Upright Sprinkler

Fire Sprinkler Head, Tyco Ultra K17, TY7153, 16.8K, Upright, 3/4"" NPT

Fire Sprinkler Head, Model K17-231, TY7151, 16.8K, Upright, 3/ 4"" NPT – Upright Sprinkler

Fire Sprinkler Head, Model K17-231, TY7151, 16.8K, Upright, 3/ 4"" NPT

Fire Sprinkler Head, Tyco Model LF II Residential, TY3934, 5.8K, Pendent, Quick Response, 1/2"" NPT – Pendent Sprinkler

Fire Sprinkler Head, Tyco Model LF II Residential, TY3934, 5.8K, Pendent, Quick Response, 1/2"" NPT

Fire Sprinkler Head, Tyco Model LF II Residential, TY2236, 4.9K, Pendent, Quick Response, 1/2"" NPT – Pendent Sprinkler

Fire Sprinkler Head, Tyco Model LF II Residential, TY2236, 4.9K, Pendent, Quick Response, 1/2"" NPT

Fire Sprinkler Head, Tyco Model LF II Residential, TY1234, 3.0K, Pendent, Quick Response, 1/2"" NPT – Pendent Sprinkler

Fire Sprinkler Head, Tyco Model LF II Residential, TY1234, 3.0K, Pendent, Quick Response, 1/2"" NPT

Fire Sprinkler Head, Tyco ESFR-14, TY6236, 14.0K, Pendent, Early Suppression Fast Response, 3/4"" NPT – ESFR Sprinkler

Fire Sprinkler Head, Tyco ESFR-14, TY6236, 14.0K, Pendent, Early Suppression Fast Response, 3/4"" NPT

Fire Sprinkler Head, Tyco ESFR-1, TY6226, 14.0K, Pendent, Early Suppression Fast Response, 3/4"" NPT – ESFR Sprinkler

Fire Sprinkler Head, Tyco ESFR-1, TY6226, 14.0K, Pendent, Early Suppression Fast Response, 3/4"" NPT

F3QR56 Horizantal Sidewall, Quick Response , Dry Sprinkler 1/2"" Orifice – Sidewall Sprinkler

F3QR56 Horizantal Sidewall, Quick Response , Dry Sprinkler 1/2"" Orifice

Model DH80 Recesses Model DH80 Concealed Fast Response, EC Sprinkler – Concealed Sprinkler

Model DH80 Recesses Model DH80 Concealed Fast Response, EC Sprinkler

DH56 Concealed—Sprinkler and Cup Only, HSW EC LH , ½"" Npt – Concealed Sprinkler

DH56 Concealed—Sprinkler and Cup Only, HSW EC LH , ½"" Npt

P25 ESFR Pendent Sprinklers – ESFR Sprinkler

P25 ESFR Pendent Sprinklers

Model P22 ESFR Pendent Sprinklers – ESFR Sprinkler

Model P22 ESFR Pendent Sprinklers

N25 ESFR Pendent Sprinklers – ESFR Sprinkler

N25 ESFR Pendent Sprinklers

Model JL-14 /JL17 Pendent ESFR Sprinkler

Model JL-14 /JL17 Pendent ESFR Sprinkler

G XLO Series Sprinkler Upright, Pendent – Pendent Sprinkler

G XLO Series Sprinkler Upright, Pendent

F1FR Pendent Sprinkler, HT, K:115, ¾"" Npt

F1FR Pendent Sprinkler, HT, K:115, ¾"" Npt

F1FR56 Sprinkler, Horizontal Wall type, QR, K 80, ½"" Npt – Fire Sprinkler

F1FR56 Sprinkler, Horizontal Wall type, QR, K 80, ½"" Npt

F1 Fire Sprinkler, ST, 17/32"" Orifice, K:115, ¾"" Npt, SR

F1 Fire Sprinkler, ST, 17/32"" Orifice, K:115, ¾"" Npt, SR

F1FR56 Quick Flush EC8 - ½"" Orifice, ½"" NPT Threads (15MM) – Fire Sprinklers & Nozzles

F1FR56 Quick Flush EC8 - ½"" Orifice, ½"" NPT Threads (15MM)

Reliable Residential Dry Sprinkler (UL Listed) – Fire Sprinkler

Reliable Residential Dry Sprinkler (UL Listed)

Bulletin 052

Reliable Model F3-80 Series Standard-Response Dry Sprinkler K-factor 8.0 (115 metric) – Fire Sprinkler

Reliable Model F3-80 Series Standard-Response Dry Sprinkler K-factor 8.0 (115 metric)

Bulletin 060

Reliable Model F3QR80 Series Quick-Response Dry Sprinkler K-factor 8.0 (115 metric) – Fire Sprinkler

Reliable Model F3QR80 Series Quick-Response Dry Sprinkler K-factor 8.0 (115 metric)

Bulletin 061

Reliable Model F3-56 Series Standard-Response Dry Sprinkler K-factor 5.6 (80 metric) – Fire Sprinkler

Reliable Model F3-56 Series Standard-Response Dry Sprinkler K-factor 5.6 (80 metric)

Bulletin 153

Reliable Model DH Series Quick Response Extended Coverage Horizontal Sidewall Sprinklers – Fire Sprinkler

Reliable Model DH Series Quick Response Extended Coverage Horizontal Sidewall Sprinklers

Bulletin 015

Reliable Model G6-80 Concealed Quick Response Extended Coverage Sidewall Sprinkler – Fire Sprinkler

Reliable Model G6-80 Concealed Quick Response Extended Coverage Sidewall Sprinkler

Bulletin 047

Reliable Model GFR VELO ECOH Extended Coverage Ordinary Hazard Sprinkler – Fire Sprinkler

Reliable Model GFR VELO ECOH Extended Coverage Ordinary Hazard Sprinkler

Bulletin 160

Reliable Model SWC Extended Coverage Concealed Horizontal Sidewall Sprinkler – Fire Sprinkler

Reliable Model SWC Extended Coverage Concealed Horizontal Sidewall Sprinkler

Bulletin 163

Reliable Model MBEC-14 Extended Coverage Horizontal Sidewall Sprinkler K14.0 (200 metric) – Fire Sprinkler

Reliable Model MBEC-14 Extended Coverage Horizontal Sidewall Sprinkler K14.0 (200 metric)

Bulletin 169

Reliable Model G4XLO EC Quick Response and Standard Response Extended Coverage – Fire Sprinkler

Reliable Model G4XLO EC Quick Response and Standard Response Extended Coverage

Bulletin 171

Reliable Model F1S5 Series Special Response Standard Spray Sprinklers – Fire Sprinkler

Reliable Model F1S5 Series Special Response Standard Spray Sprinklers

Bulletin 024

Reliable Model G5 Series Sprinklers Standard Spray, Flat – Fire Sprinkler

Reliable Model G5 Series Sprinklers Standard Spray, Flat

Bulletin 034

Reliable Model KFR56-300 Series Sprinklers Quick-response, Standard Spray Fusible Link Sprinklers – Fire Sprinkler

Reliable Model KFR56-300 Series Sprinklers Quick-response, Standard Spray Fusible Link Sprinklers

Bulletin 039

Reliable Model G6-56 Concealed Quick Response Standard Spray Sidewall Sprinkler – Fire Sprinkler

Reliable Model G6-56 Concealed Quick Response Standard Spray Sidewall Sprinkler

Bulletin 050

Reliable Model F1FR-SS Series Stainless Steel Sprinklers Standard spray, quick-response – Fire Sprinkler

Reliable Model F1FR-SS Series Stainless Steel Sprinklers Standard spray, quick-response

Bulletin 065

Reliable F1FR28 Series Quick-Response Sprinklers K-factor 2.8 (40) – Fire Sprinkler

Reliable F1FR28 Series Quick-Response Sprinklers K-factor 2.8 (40)

Bulletin 072

Reliable F1FR42 Series Quick-Response Sprinklers K-factor 4.2 (60) – Fire Sprinkler

Reliable F1FR42 Series Quick-Response Sprinklers K-factor 4.2 (60)

Bulletin 073

Reliable Model GQR112 Series Sprinklers Storage and Non-Storage Sprinklers K11.2 (160 metric) – Fire Sprinkler

Reliable Model GQR112 Series Sprinklers Storage and Non-Storage Sprinklers K11.2 (160 metric)

Bulletin 081

Reliable Model G4-11 Sprinkler Standard Spray, Flat – Fire Sprinkler

Reliable Model G4-11 Sprinkler Standard Spray, Flat

Bulletin 086

Reliable Model GFR Series Quick-Response Sprinklers – Fire Sprinkler

Reliable Model GFR Series Quick-Response Sprinklers

Bulletin 131

Reliable F1FR40 (VdS) Standard Spray Sprinkler K-factor 4.0 (57) – Fire Sprinkler

Reliable F1FR40 (VdS) Standard Spray Sprinkler K-factor 4.0 (57)

Bulletin 183

Reliable F1XLH and F1FRXLH Series Standard Spray Sprinklers K-factor 4.2 (60 metric) – Fire Sprinkler

Reliable F1XLH and F1FRXLH Series Standard Spray Sprinklers K-factor 4.2 (60 metric)

Bulletin 184

Reliable Model RFC Series Residential Sprinklers Flat – Fire Sprinkler

Reliable Model RFC Series Residential Sprinklers Flat

Bulletin 006

Reliable Model F1Res LL Series Glass Bulb Residential Sprinklers – Fire Sprinkler

Reliable Model F1Res LL Series Glass Bulb Residential Sprinklers

Bulletin 033

Reliable Model RFS42 Residential Flat Concealed Horizontal Sidewall Sprinkler – Fire Sprinkler

Reliable Model RFS42 Residential Flat Concealed Horizontal Sidewall Sprinkler

Bulletin 048

Reliable Model F1Res Series Glass Bulb Residential Sprinklers – Fire Sprinkler

Reliable Model F1Res Series Glass Bulb Residential Sprinklers

Bulletin 135

Reliable Model RFC49plus & RFC49LLplus Residential Sprinklers Flat – Fire Sprinkler

Reliable Model RFC49plus & RFC49LLplus Residential Sprinklers Flat

Bulletin 188

Reliable Model KRes Series Fusible Link Residential Sprinklers – Fire Sprinkler

Reliable Model KRes Series Fusible Link Residential Sprinklers

Bulletin 935

Reliable Model F4FR-NF Non-Ferrous Quick Response Concealed Automatic Sprinkler – Fire Sprinkler

Reliable Model F4FR-NF Non-Ferrous Quick Response Concealed Automatic Sprinkler

Bulletin 002

Reliable Model F1FR-FS Series Quick-Response Flat Spray Sprinklers – Fire Sprinkler

Reliable Model F1FR-FS Series Quick-Response Flat Spray Sprinklers

Bulletin 022

Reliable Model F1S5-FS42, F1S5-FS56, & F1S5-FS80 Special Response Flat Spray Sprinklers – Fire Sprinkler

Reliable Model F1S5-FS42, F1S5-FS56, & F1S5-FS80 Special Response Flat Spray Sprinklers

Bulletin 023

Reliable Model F1FR-FS LO Large Orifice Quick Response Flat Spray Sprinkler – Fire Sprinkler

Reliable Model F1FR-FS LO Large Orifice Quick Response Flat Spray Sprinkler

Bulletin 037

Reliable Model KFR-CCS Combustible Concealed Space Sprinkler K-factor 5.6 (80) – Fire Sprinkler

Reliable Model KFR-CCS Combustible Concealed Space Sprinkler K-factor 5.6 (80)

Bulletin 044

Reliable Model DD56-6, DD56-27, DD80-6, DD80-27, DS56, GP56, AH42, & AH56 Sprinklers – Fire Sprinkler

Reliable Model DD56-6, DD56-27, DD80-6, DD80-27, DS56, GP56, AH42, & AH56 Sprinklers

Bulletin 056

Reliable Model F1-FTR Fixed Temperature Release Pilot Line Detector – Fire Sprinkler

Reliable Model F1-FTR Fixed Temperature Release Pilot Line Detector

Bulletin 180

Reliable Model WP Specific Application Window Sprinklers – Fire Sprinkler

Reliable Model WP Specific Application Window Sprinklers

Bulletin 181

Reliable F1-80 Series Standard-Response Sprinklers K-factor 8.0 (115) – Fire Sprinkler

Reliable F1-80 Series Standard-Response Sprinklers K-factor 8.0 (115)

Bulletin 062

Reliable Model F1-SS Series Stainless Steel Sprinklers Standard spray, standard-response – Fire Sprinkler

Reliable Model F1-SS Series Stainless Steel Sprinklers Standard spray, standard-response

Bulletin 064

Reliable F1-28 Series Standard-Response Sprinklers K-factor 2.8 (40) – Fire Sprinkler

Reliable F1-28 Series Standard-Response Sprinklers K-factor 2.8 (40)

Bulletin 066

Reliable F1-42 Series Standard-Response Sprinklers K-factor 4.2 (60) – Fire Sprinkler

Reliable F1-42 Series Standard-Response Sprinklers K-factor 4.2 (60)

Bulletin 067

Reliable F1-80-300 Series Standard Response Sprinklers K-factor 8.0 (115) – Fire Sprinkler

Reliable F1-80-300 Series Standard Response Sprinklers K-factor 8.0 (115)

Bulletin 076

Reliable Model G Series Standard-Response Sprinklers – Fire Sprinkler

Reliable Model G Series Standard-Response Sprinklers

Bulletin 110

Reliable The Concealer Concealed Pendent Sprinkler – Fire Sprinkler

Reliable The Concealer Concealed Pendent Sprinkler

Bulletin 121

Reliable G4-300 Concealer Concealed Pendent Sprinkler – Fire Sprinkler

Reliable G4-300 Concealer Concealed Pendent Sprinkler

Bulletin 161

Reliable Model P22 ESFR Pendent Sprinklers – ESFR Sprinkler

Reliable Model P22 ESFR Pendent Sprinklers

Bulletin 069

Reliable Model P25 ESFR Pendent Sprinklers – ESFR Sprinkler

Reliable Model P25 ESFR Pendent Sprinklers

Bulletin 070

Reliable Model GSR112 Series Sprinklers Storage and Non-Storage Sprinklers K11.2 (160 metric) – Fire Sprinkler

Reliable Model GSR112 Series Sprinklers Storage and Non-Storage Sprinklers K11.2 (160 metric)

Bulletin 080

Reliable Model M336 ESFR Pendent Sprinklers – ESFR Sprinkler

Reliable Model M336 ESFR Pendent Sprinklers

Bulletin 087

Reliable Model GXLO Series Sprinklers Storage and Non-Storage Sprinklers K11.2 (160 metric) – Fire Sprinkler

Reliable Model GXLO Series Sprinklers Storage and Non-Storage Sprinklers K11.2 (160 metric)

Bulletin 129

Reliable Intermediate Level Sprinklers – Fire Sprinkler

Reliable Intermediate Level Sprinklers

Bulletin 187

Reliable Model N25 ESFR Pendent Sprinkler – ESFR Sprinkler

Reliable Model N25 ESFR Pendent Sprinkler

Bulletin 909

Reliable Model TNL280 Pendent Spray Nozzle

Reliable Model TNL280 Pendent Spray Nozzle

Bulletin 099

Reliable Model B and FM Open Window and Open Cornice Spray Nozzles

Reliable Model B and FM Open Window and Open Cornice Spray Nozzles

Bulletin 103

Reliable Open Sprinklers for Deluge Systems – Fire Sprinkler

Reliable Open Sprinklers for Deluge Systems

Bulletin 104

Reliable Model HV High Velocity Spray Nozzles

Reliable Model HV High Velocity Spray Nozzles

Bulletin 105

Reliable Model MV Medium Velocity Directional Spray Nozzles

Reliable Model MV Medium Velocity Directional Spray Nozzles

Bulletin 106

Tyco Series DS-8 – 8.0 K-factor, Dry-Type Sprinklers – Fire Sprinkler

Tyco Series DS-8 – 8.0 K-factor, Dry-Type Sprinklers

TFP503

Tyco Series DS-C Dry Type Sprinklers 5.6K Concealed Pendent Standard and Quick Response – Fire Sprinkler

Tyco Series DS-C Dry Type Sprinklers 5.6K Concealed Pendent Standard and Quick Response

TFP515

Tyco Series DS-ECC Dry Type Sprinklers 5.6K Pendent Concealed Quick Response – Fire Sprinkler

Tyco Series DS-ECC Dry Type Sprinklers 5.6K Pendent Concealed Quick Response

TFP518

Tyco Series DS-2 Dry-Type Sprinklers 11.2K Pendent Standard and Quick Response – Fire Sprinkler

Tyco Series DS-2 Dry-Type Sprinklers 11.2K Pendent Standard and Quick Response

TFP530

Tyco Series DS-2 Dry-Type Sprinklers 11.2K Pendent Extended Coverage, Light and Ordinary – Fire Sprinkler

Tyco Series DS-2 Dry-Type Sprinklers 11.2K Pendent Extended Coverage, Light and Ordinary

TFP540

Tyco Series DS-3 Dry-Type Sprinklers 11.2K Horizontal Sidewall Standard Response – Fire Sprinkler

Tyco Series DS-3 Dry-Type Sprinklers 11.2K Horizontal Sidewall Standard Response

TFP550

Tyco Series EC-8 – 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers – Fire Sprinkler

Tyco Series EC-8 – 8.0 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers

TFP223

Tyco Series EC-8C – 8.0 K-factor Special Application, Quick Response Pendent and Recessed Pendent Sprinklers – Fire Sprinkler

Tyco Series EC-8C – 8.0 K-factor Special Application, Quick Response Pendent and Recessed Pendent Sprinklers

TFP226

Tyco Series EC-5 – 5.6 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers – Fire Sprinkler

Tyco Series EC-5 – 5.6 K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers

TFP228

Tyco Model SW-20 and SW-24 – 11.2 K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers – Fire Sprinkler

Tyco Model SW-20 and SW-24 – 11.2 K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers

TFP230

Tyco Model ELOC – 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers – Fire Sprinkler

Tyco Model ELOC – 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers

TFP250

Tyco Series RFII-MRI – 5.6 K-factor Non-Magnetic Concealed Pendent Sprinklers – Fire Sprinkler

Tyco Series RFII-MRI – 5.6 K-factor Non-Magnetic Concealed Pendent Sprinklers

TFP262

Tyco Series RFII-C – 5.6 K-factor Special Application Royal Flush II Quick Response – Fire Sprinkler

Tyco Series RFII-C – 5.6 K-factor Special Application Royal Flush II Quick Response

TFP263

Tyco Model CHEC–8.0 K-factor Concealed Horizontal Extended Coverage Quick Response – Fire Sprinkler

Tyco Model CHEC–8.0 K-factor Concealed Horizontal Extended Coverage Quick Response

TFP265

Tyco Model RFIII – 8.0 K-factor Flat Plate Concealed Horizontal Extended Coverage – Fire Sprinkler

Tyco Model RFIII – 8.0 K-factor Flat Plate Concealed Horizontal Extended Coverage

TFP270

Tyco Series TY-FRL – 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinkler – Fire Sprinkler

Tyco Series TY-FRL – 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinkler

TFP280

Tyco Model EC-HS – 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers – Fire Sprinkler

Tyco Model EC-HS – 80 K-factor, Quick Response Extended Coverage Horizontal Sidewall Sprinklers

TFP288

Tyco Series TY-FRB – 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers – Fire Sprinkler

Tyco Series TY-FRB – 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers

TFP296

Tyco Series EC-5 – 5.6 K-factor Extended Coverage Horizontal Sidewall Sprinklers – Fire Sprinkler

Tyco Series EC-5 – 5.6 K-factor Extended Coverage Horizontal Sidewall Sprinklers

TFP298

Tyco Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity

Tyco Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity

TFP800

Tyco Type D4a PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity

Tyco Type D4a PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity

TFP806

Tyco Type MV-R Reverse Action and Type MV-T Tank Top Medium Velocity Open Nozzles

Tyco Type MV-R Reverse Action and Type MV-T Tank Top Medium Velocity Open Nozzles

TFP809

Tyco Model F822 through F834 MULSIFYRE Directional Spray Nozzles, Open, High Velocity

Tyco Model F822 through F834 MULSIFYRE Directional Spray Nozzles, Open, High Velocity

TFP810

Tyco Model F822S Through F834S MULSIFYRE Directional Spray Nozzles

Tyco Model F822S Through F834S MULSIFYRE Directional Spray Nozzles

TFP811

Tyco Type HV High Velocity Directional Spray Nozzles, Open, Non-Automatic

Tyco Type HV High Velocity Directional Spray Nozzles, Open, Non-Automatic

TFP815

Tyco Issue A and B Exposure Protection Sprinklers Window Type – Fire Sprinkler

Tyco Issue A and B Exposure Protection Sprinklers Window Type

TFP835

Tyco Model B-1 – 3.0 K-factor Upright and Pendent Foam-Water Sprinklers – Fire Sprinkler

Tyco Model B-1 – 3.0 K-factor Upright and Pendent Foam-Water Sprinklers

TFP840

Tyco Series LFII Residential Sprinklers 5.8 K-factor – Fire Sprinkler

Tyco Series LFII Residential Sprinklers 5.8 K-factor

TFP401

Tyco Series LFII Residential Sprinklers 6.9 K-factor Pendent/Recessed Pendent/Concealed – Fire Sprinkler

Tyco Series LFII Residential Sprinklers 6.9 K-factor Pendent/Recessed Pendent/Concealed

TFP408

Tyco Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall – Fire Sprinkler

Tyco Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall

TFP410

Tyco Series LFII Residential 4.9 K-factor Polymeric Concealed Pendent Sprinkler Flat Plate – Fire Sprinkler

Tyco Series LFII Residential 4.9 K-factor Polymeric Concealed Pendent Sprinkler Flat Plate

TFP447

Tyco Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type – Fire Sprinkler

Tyco Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type

TFP460

Tyco Series TY-B – 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers – Fire Sprinkler

Tyco Series TY-B – 5.6 and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers

TFP151

Tyco Models BB, SD, HIP and AP Specific Application Sprinklers for Attics – Fire Sprinkler

Tyco Models BB, SD, HIP and AP Specific Application Sprinklers for Attics

TFP610

Tyco Model WS Specific Application Window Sprinklers – Fire Sprinkler

Tyco Model WS Specific Application Window Sprinklers

TFP620

Tyco Model CC1 – 2.8 K-factor Combustible Concealed Space Sprinklers – Fire Sprinkler

Tyco Model CC1 – 2.8 K-factor Combustible Concealed Space Sprinklers

TFP630

Tyco Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinkler – Fire Sprinkler

Tyco Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinkler

TFP635

Tyco Model FSC 80 K-factor Flush Sprinkler, Pendent Quick Response, Standard Coverage – Fire Sprinkler

Tyco Model FSC 80 K-factor Flush Sprinkler, Pendent Quick Response, Standard Coverage

TFP645

Tyco Model TFP PH2 – 5.6 K-factor Institutional Pendent Sprinklers – Fire Sprinkler

Tyco Model TFP PH2 – 5.6 K-factor Institutional Pendent Sprinklers

TFP650

Tyco RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response – Fire Sprinkler

Tyco RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response

TFP651

Tyco Series TY-FRB – 5.6 and 8.0 K-factor Conventional (Old Style) Sprinklers – Fire Sprinkler

Tyco Series TY-FRB – 5.6 and 8.0 K-factor Conventional (Old Style) Sprinklers

TFP666

Tyco Series TY-B and TY-FRB Sprinklers Alternate Materials of Construction Stainless Steel – Fire Sprinkler

Tyco Series TY-B and TY-FRB Sprinklers Alternate Materials of Construction Stainless Steel

TFP680

Tyco Series TY-L – 5.6 and 8.0 K-factor Stainless Steel Pendent and Recessed Pendent Sprinklers – Fire Sprinkler

Tyco Series TY-L – 5.6 and 8.0 K-factor Stainless Steel Pendent and Recessed Pendent Sprinklers

TFP683

Tyco Series TY-FRL – 8.0 K-factor Upright and Pendent Sprinklers – Fire Sprinkler

Tyco Series TY-FRL – 8.0 K-factor Upright and Pendent Sprinklers

TFP130

Tyco Series TY-B – 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers – Fire Sprinkler

Tyco Series TY-B – 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers

TFP161

Tyco Series TY-FRB – 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers – Fire Sprinkler

Tyco Series TY-FRB – 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers

TFP171

Tyco Series RFII-MRI – 5.6 K-factor Non-Magnetic Concealed Pendent Sprinklers – Fire Sprinkler

Tyco Series RFII-MRI – 5.6 K-factor Non-Magnetic Concealed Pendent Sprinklers

TFP182

Tyco Series TY-L – 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers – Fire Sprinkler

Tyco Series TY-L – 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers

m

Tyco Model ESFR-22 22.4 K-factor Pendent Sprinklers Early Suppression, Fast Response – ESFR Sprinkler

Tyco Model ESFR-22 22.4 K-factor Pendent Sprinklers Early Suppression, Fast Response

TFP321

Tyco Ultra K17 – 16.8 K-factor Upright Control Mode Specific Application Sprinkler – Fire Sprinkler

Tyco Ultra K17 – 16.8 K-factor Upright Control Mode Specific Application Sprinkler

TFP330

Tyco Model LD – 11.2 K-factor Large Drop Upright Sprinkler – Fire Sprinkler

Tyco Model LD – 11.2 K-factor Large Drop Upright Sprinkler

TFP335

Tyco Series ELO-231 – 11.2 K-factor Upright and Pendent Sprinklers – Fire Sprinkler

Tyco Series ELO-231 – 11.2 K-factor Upright and Pendent Sprinklers

TFP340

Tyco Series TY-B – 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers – Fire Sprinkler

Tyco Series TY-B – 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers

TFP351

Tyco Series TY-FRB – 5.6 K-factor Upright and Pendent Intermediate Level Sprinklers – Fire Sprinkler

Tyco Series TY-FRB – 5.6 K-factor Upright and Pendent Intermediate Level Sprinklers

TFP357

Fire sprinklers: how to choose

What is the difference between pendent and upright sprinklers?

A pendent sprinkler is installed pointing down from the pipe, an upright sprinkler points up above the pipe. The choice depends on the ceiling type and pipe position.

When are quick response sprinklers used?

Quick response sprinklers react to heat faster and are widely used where people are present, such as hotels and offices. The final choice depends on the system design and the applicable standard.

How do I get a sprinkler price?

Use the “Ask for Price” button on the product page or message us on WhatsApp with the model, quantity and project details, and we will reply quickly.